Reliability of the Center of Pressure Parameters after ACL Reconstruction Surgery

AUTHORS

Hoda Niknam 1 , Alireza Sarmadi 1 , * , Mahiar Salavati 2 , Firooz Madadi 3

AUTHORS INFORMATION

1 Department of Physiotherapy, Tarbiat modares University, Tehran, Iran

2 Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran

3 Department of Orthopedic, Shahid Beheshti University, Tehran, Iran

How to Cite: Niknam H, Sarmadi A, Salavati M, Madadi F. Reliability of the Center of Pressure Parameters after ACL Reconstruction Surgery, Zahedan J Res Med Sci. 2013 ; 15(4):e93006.

ARTICLE INFORMATION

Zahedan Journal of Research in Medical Sciences: 15 (4); e93006
Published Online: November 05, 2012
Article Type: Research Article
Received: April 19, 2011
Accepted: May 28, 2011

Crossmark

CHEKING

READ FULL TEXT
Abstract

Background : The elicited parameters from the center of pressure (COP) of patients after surgery of the anterior cruciate ligament are proper indications for estimating balance after surgery and rehabilitation. Thus, making sure about repeatability of COP parameters which can determine the knee joint after the knee reconstruction surgery is very important. This study measures repeatability rate of some COP parameters after reconstructing anterior cruciate ligament in various positions.
Materials and Methods : In this study, 15 athlete men (mean age: 27±5) after 4-6 months since repair of their anterior cruciate ligament were included they have been selected through simple non-probability sampling method. The study was conducted in biomechanics lab of Tarbiat Modares University in 2010. Assessment of balance was done with open/closed eyes, with/without foam using force platform in two sessions with 48 hours interval.
Results : The external-internal amplitude (0.86), external-internal standard deviation (0.86), phase plane (0.82) and area oscillation (0.81) were among parameters which showed the most repeatability. The average oscillation of anterior - posterior frequency (0.6) showed the lowest repeatability.
Conclusion : A number of parameters caused by oscillation of COP show high rate of repeatability after reconstructing anterior cruciate ligament which can be used as an assessment of patients condition after reconstruction of the anterior cruciate ligament.

Keywords

Reliability ACL Center of pressure

© 2013, Zahedan Journal of Research in Medical Sciences. This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.